Aqualink · Gateway simulator

Every command.
A clear response.

Open the valves, confirm their state, and try a pump command. See why the gateway accepts or holds a start.

Browser model of gateway rules. Replies and device feedback are simulated; no equipment is connected.

Understand the system ↗
01Operator commandSMS · Wi-Fi · Cloud
02SmartAgriGatewayLocal pump interlocks
03Equipment feedbackRS485 · LoRa 868 MHz
Pump · RS485Stopped
Catalogue pump controller0x20

Pump controller

Start is checked against both linked valves.

Wired valve · OBUSClosed
Catalogue valve controller0x01 / R1

Valve controller

Relay 1 must be active before the pump starts.

Wireless actuator · LoRaClosed
VDrive868 MHz · Position feedbackLoRa / 1

Motorized actuator

Sending a command and confirming an open position are separate steps.

Start held

The wired valve must be open.

Explore the safety rules

What happens if…

Run a local scenario, then try starting the pump again.

Advance simulated time
This session

Command history

Local only
  1. Your first action will appear here.
Show protocol details
—

The pump and valve addresses match the default link in the gateway firmware. This view models successful bus replies; it is not a full firmware emulator.

Read the state before starting.

  1. Open the wired valve.The relay state must confirm an active output.
  2. Send open to the actuator.Confirm its simulated feedback at 100% open.
  3. Try the pump command.The gateway checks recovery time, dry-run lockout, and both valve states.